If you need a new generator, or you have an existing generator that needs service or repair, our proactive and well thought out plans are successful!

    

Someone will contact you today!

 

Send an email with your information.

 

Contact Form.

 

 

 

Do you have questions about how to check or change your oil during a power outage? 

 

Send an email with your question.

What is a managed, whole house generator? 

 

Size is important, a load calculation for your electrical needs will be necessary, we can help. 

 

How much of your home can be covered with the generator, with the correct management, all of it!

 

Click here if you need assistance.

 

Office:    

919-245-0200

 

Toll Free:

1-888-919-5210

 

Click here to contact us!

ncgenerators.com

Kohler Generators in the Raleigh Durham, Chapel Hill & Greensboro area.

E&W Electrical, LLC
515 Meadowlands Dr 515
Hillsborough, North Carolina 27278
Phone: +1 919 245-0200+1 919 245-0200
Fax: +1 919 245-0202
E-mail Address:

Kohler has been manufacturing generators since 1920.  The product was developed  to provide electricity for the well pumps needed to support their plumbing products. 

 

Kohler quality is hard to match and everything used on the product is made in the USA and the pride shows!  Engine response associated with a generator is very important when determining brand, Kohler's response is as good as it gets.  

 

Their product offerings provide for generator standby coverage for any size structure or load and their control platforms are well tested and thought out.  Kohler stands behind its product with a 5 year limited warranty!  For all E&W Electrical, LLC installations we provide a 5 year extended warranty so that if anything goes wrong with the machine, all warrantable items are covered at 100%.

 

Kohler's philosophy is to develop relationships with entities committed to quality.  The dealer networks that exist and continues to grow is made up of companies that are qualified to represent the Kohler product.  Click on this link to see Kohler's residential and commercial offerings, Kohler generators

 

If you have any questions please notify our sales manager, Michael Williams, sales@ncgenerators.com

 

E&W Electrical, LLC is very excited about our future with Kohler Generators going forward.  Put both our experiences, Kohler & E&W, to work for you! 

Fuel Management and Checking the Oil Level During Extended Power Outages.

You may not want to run your generator 24 hours a day during an extended utility power outage.  Fuel management performed correctly by taking the correct steps can save you money however you should not just shut the generator off, there is a procedure.

 

Utility power outages can last for days.  Manufacturers recommend that checking the oil levels for the generator engines during these extended outage should occur every two to three days.  There is a procedure which should be followed for checking the oil level during the extended power outages.

 

If you decide to turn the generator off during a utility power outage the following steps should be followed.

 

  1. Locate the circuit breaker inside the generator usually insided the control panel and turn the breaker off.  This disconnects the load from the generator, all power to the structure being served will go off.
  2. Let the generator engine continue to run for 5 minutes and then set the generator functions to off using the selector switch of the generator's controller.
  3. If you have turned the generator off to check the oil level, wait 10 minutes before checking.  If the oil level is low, refill with the oil type recommended by the manufacturer, be careful not to overfill.
  4. When you are ready to restart the generator, switch the selector switch of the controller to AUTO and wait for the generator to start.  After the engine has started and is running, wait 30 seconds to allow the engine to stabilize and then turn the generator circuit breaker back on.

 

Remote Monitoring for Kohler Generators

Remote monitoring with an annual contract is becoming the choice for a lot of our service contract customers.  The 24/7 attention to each of thousands of generators combined with correct and comprehensive annual service allows us to provide failure rates of less than 1%. 

 

The Kohler approach to monitoring is to connect directly to the structure ehternet netork thru the router to enable connection between the generator controller and the Kohler server's so that notifications can be sent to the end user or the company taking care of the generator.

 

If the end user is away from home, without the monitoring package, a power loss could occur and as with any mechanical product, a fault could occur and there is no one to notify the company taking care of the system.  This can result in several type loss scenarios such as food, water damage, etc.; the monitoring can put an end to these type loss scenarios.

OnCue Plus Operation Manual
Gives instructiion for OnCue Operations
OnCue_Plus_Operation_Manual_(manual_tp69[...]
Adobe Acrobat document [1.8 MB]
OnCue Plus Installation Manual
Covers installation of the OnCue Plus application.
OnCue_Plus_Installation_Instructions_RDC[...]
Adobe Acrobat document [865.2 KB]
Print | Sitemap
Under the DMCA or Digital Millennium Copyright Act, all content published online is protected under copyright law, regardless of it having the copyright symbol on the page. Any content, no matter the form it takes (whether digital, print, or media) is protected under copyright law. The author takes no responsibility for the timeliness, accuracy, completeness or quality of the information provided. The author is in no event liable for damages of any kind incurred or suffered as a result of the use or non-use of the information presented on this website or the use of defective or incomplete information unless the author has been acting deliberately or in a wantonly negligent manner. The contents of this website are subject to confirmation and not binding. The author expressly reserves the right to alter, amend or remove pages, whole and in part, without prior notice or to discontinue publication for a period of time or even completely.